NCC 2019 Volume Two Amendment 1
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c
Part 3.10.1 Swimming pools

Part 3.10.1 Swimming pools

Appropriate Performance Requirements

Appropriate Performance Requirement

  1. Where an alternative swimming pool safety barrier is proposed as a Performance Solution to that described in Part 3.10.1 that proposal must comply with—
    1. Performance RequirementP2.7.1; and
    1. the relevant Performance Requirements determined in accordance with A2.2(3) and A2.4(3) as applicable.
  2. Where an alternative swimming pool water recirculation system is proposed as a Performance Solution to that described in Part 3.10.1, that proposal must comply with—
    1. Performance RequirementP2.7.2; and
    2. the relevant Performance Requirements determined in accordance with A2.2(3) and A2.4(3) as applicable.

Explanatory information:

Explanatory information:

Part 3.12.5 contains requirements for swimming pool and spa pool heating and pumping. In specific circumstances, Part 3.12.5 requires a swimming pool or spa pool to have a cover to reduce evaporation and subsequent heat loss, and time switches to control the operation of the heater.

In addition to the requirements of this Part, a swimming pool must comply with the structural requirements of the Housing Provisions. The structural requirements refer to the swimming pool being designed and constructed to withstand any combinations of loads and other actions to which it may reasonably be subjected and the structural resistance of the materials and forms of construction used in the swimming pool.

Acceptable Construction Manuals

3.10.1.0

(a)

Performance RequirementP2.7.1 is satisfied for a swimming pool with a depth of water more than 300 mm and which is associated with a Class 1 building, if it has safety barriers installed in accordance with AS 1926.1 and AS 1926.2.

(b)

Performance RequirementP2.7.2 is satisfied for a water recirculation system of a swimming pool with a depth of water more than 300 mm, if it complies with AS 1926.3.

Explanatory information:

Explanatory information:

The BCA definition of swimming pool is specific in including a bathing or wading pool and a spa. The requirements of AS 1926.3 apply to all types of pools defined as swimming pools under the BCA, irrespective of the definition in the Standard.

The swimming pool water recirculation system requirements seek to minimise the risk of entrapment or injury of people using the swimming pool and provide for the safe operation of skimmer boxes and outlet systems.

State and Territory Variations

State and Territory Variations

In New South Wales delete 3.10.1.0(a) and insert NSW 3.10.1.0(a) as follows:

  1. Performance RequirementP2.7.1 is satisfied for a swimming pool with a depth of water more than 300 mm and which is associated with a Class 1 building, if it has safety barriers installed in accordance with:
    1. AS 1926 Parts 1 and 2; or
    2. If the swimming pool is a spa pool:
      1. The requirements of (a)(i); or
      2. Clause 9 of the Swimming Pools Regulation 2018.

Application:

Application:

NSW Part 3.10.1.0(a) applies in New South Wales to the technical construction requirements for barriers to restrict access to swimming pools, subject to out-of-ground pool walls and the walls of above ground pools, including inflatable pools, not being considered to be effective barriers.

Note: The Swimming Pools Act 1992 and the Swimming Pools Regulation 2018, applicable to swimming pools with a depth of water of more than 300 mm, regulate the circumstances in which a barrier is required and prevail in the case of any inconsistency.

2. Part 3.10.1.0(a) does not apply in Queensland.

Note: Restriction of access to swimming pools in Queensland is regulated under the Building Act 1975.

3. Part 3.10.1.0(a) does not apply in the Northern Territory.

Note: Restriction of access to swimming pools in the Northern Territory is regulated under the Swimming Pool Safety Act.

4. In South Australia delete 3.10.1.0(b) and add SA 3.10.1.0(b) as follows:

  1. Performance RequirementP2.7.2 is satisfied for a water recirculation system of a swimming pool with a depth of water more than 300 mm, if it complies with AS 1926.3. For the purpose of clause 6.1.1 of AS 1926.3, a skimmer box is an outlet and must have a means of releasing the vacuum pressure should the suction become blocked.

Explanatory information: Cross-volume considerations

Explanatory information: Cross-volume considerations

Part C2 of NCC Volume Three sets out the requirements for pumped discharge from swimming pools.