Part H2 Public transport buildings

Part H2 Public transport buildings

Note:

Note:

Part H2 contains Deemed-to-Satisfy Provisions for Class 9b and Class 10 public transport buildings additional to those contained in Parts D3, E3 and F2 that apply to public transport buildings.

H2.1 Application of Part

(a)

The Deemed-to-Satisfy Provisions of this Part apply to the passenger use areas of a Class 9b or Class 10 building used for public transport.

(b)

The Deemed-to-Satisfy Provisions of this Part take precedence where there is a difference to the Deemed-to-Satisfy Provisions of Parts D3, E3 and F2.

(c)

For an airport that does not accept regular public transport services, as defined in the Disability Standards for Accessible Public Transport 2002, only H2.8, H2.9, H2.10, H2.11, H2.12 and H2.13 of this Part apply.

(d)

Exemption 1 to A6.0(1) does not apply to this Part.

The Objectives and Functional Statements for Part H2 are contained in Sections D, E and F of this Guide. The Performance Requirements for Part H2 are contained in Sections D, E and F. Part H2 contains Deemed-to-Satisfy Provisions for Class 9b and Class 10 public transport buildings additional to those contained in Parts D3, E3 and F2 that apply to public transport buildings.
The Objectives and Functional Statements for Part H2 are contained in Sections D, E and F of this Guide. The Performance Requirements for Part H2 are contained in Sections D, E and F. Part H2 contains Deemed-to-Satisfy Provisions for Class 9b and Class 10 public transport buildings additional to those contained in Parts D3, E3 and F2 that apply to public transport buildings.
The Objectives and Functional Statements for Part H2 are contained in Sections D, E and F of this Guide. The Performance Requirements for Part H2 are contained in Sections D, E and F. Part H2 contains Deemed-to-Satisfy Provisions for Class 9b and Class 10 public transport buildings additional to those contained in Parts D3, E3 and F2 that apply to public transport buildings.
Intent

To clarify which public transport buildings are subject to Part H2 and to what extent they are subject.

Part H2 specifically relates to buildings associated with public transport services, such as railway stations, bus interchanges, airports and ferry terminals. These requirements were previously located in the Disability Standards for Accessible Public Transport 2002 (Transport Standards). Some versions of Australian Standards referred to in Part H2 may be different to those referred to in the remainder of the BCA. The correct version of the Australian Standard to be used can be determined by reference to Schedule 4.

H2.1(a) provides that the Deemed-to-Satisfy Provisions of Part H2 apply to the passenger use areas of Class 9b or Class 10 buildings used for public transport. Class 9b and Class 10 public transport buildings must also satisfy the Deemed-to-Satisfy Provisions of Parts D3, E3 and F2.

H2.1(b) provides a rule for resolving inconsistencies between these requirements imposed on public transport buildings by providing that the Deemed-to-Satisfy Provisions of Part H2 take precedence where there is a difference.

H2.1(c) provides that, as under the Transport Standards, certain requirements in Part H2 do not apply to ‘airports that do not accept regular public transport services’ as defined in the Transport Standards.

H2.1(d) provides that exemption 1 to A6.0 does not apply to Part H2 because the application of this provision to Part H2 could result in a different outcome to what would have been achieved under similar provisions that existed in the Transport Standards. Under exemption 1 to A6.0, if 10% or less of the floor area of a storey is used for a purpose which could be classified differently to the remainder of that storey, that part may be classified as being the same as the remainder.

H2.2 Accessways

(a)

An accessway must comply with AS 1428.2.

(b)

If an accessway branches into 2 or more parallel tracks—

(i)

the ends of each track must be on the main pedestrian traffic routes; and

(ii)

the parallel tracks must have equal convenience and be located as close as practicable to the main pedestrian branch.

(c)

The minimum unobstructed width of an accessway must be 1.2 m, except that—

(i)

the minimum unobstructed width of a moving walkway forming part of an accessway may be not less than 850 mm; and

(ii)

the minimum unobstructed width of a doorway in an accessway may be not less than 850 mm.

(d)

Poles, columns, stanchions, bollards and fixtures must not project into an accessway.

(e)

Obstacles that abut an accessway must have a luminance contrast with a background of not less than 30%.

(f)

Manoeuvring areas that allow a 180 degree wheelchair turn must comply with clause 6.2 of AS 1428.2.

(g)

A passing area must be provided at least every 6 m along any two-way accessway that is less than 1800 mm wide.

(h)

Ground and floor surfaces must comply with clause 9 of AS 1428.2 and AS 1428.1. Supplement 1 provides criteria for the selection of floor surfaces.

(i)

The requirements of D3.3(c)(ii) do not apply to Class 9b or Class 10 public transport buildings.

Intent

To specify requirements for accessways in buildings covered by Part H2.

The requirements for accessways in H2.2 were previously located in the Transport Standards.

Accessways and manoeuvring areas may be for other purposes, such as standing areas, but it is expected that public transport passengers will be able to transit them and that they remain available for use by people with a disability when required.

Hazards created by poles, columns, stanchions, bollards and fixtures alongside accessways should be avoided. For example, the use of short posts to prevent delivery vehicles from driving onto parts of pedestrian areas, or commercial signs projecting from walls should be avoided.

H2.2(g) requires passing areas to be provided in prescribed locations, with the intent that they be wide enough for 2 people, each using a mobility aid, to pass one another.

H2.3 Ramps

(a)

A ramp forming part of an accessway must comply with clause 8 of AS 1428.2.

(b)

The requirements of D3.11(a) do not apply to Class 9b or Class 10 public transport buildings.

Intent

To specify requirements for ramps in buildings covered by Part H2.

The requirements for ramps in H2.3 were previously located in the Transport Standards.

H2.3 provides requirements for accessible ramps in public transport buildings. Ramps forming part of an accessway must comply with clause 8 of AS 1428.2.

H2.3(b) provides that D3.11(a), which limits the combined vertical rise of connected ramps to 3.6 m, does not apply to buildings covered by Part H2.

H2.4 Handrails and grabrails

(a)

A handrail must comply with clause 10.1 of AS 1428.2.

(b)

Handrails must be placed along an accessway wherever passengers are likely to require additional support or passive guidance.

(c)

A grabrail must comply with clause 10.2 of AS 1428.2.

(d)

A grabrail or handrail must be provided at fixed locations where passengers are required to pay fares.

Intent

To specify requirements for handrails and grabrails in buildings covered by Part H2.

The requirements for handrails and grabrails in H2.4 were previously located in the Transport Standards.

H2.4 provides requirements for handrails and grabrails in public transport buildings. H2.4(b) provides that handrails must be placed along an accessway to assist wherever passengers are likely to require additional support or guidance, such as changes of level, ramps, a narrowing or a change of direction of an accessway. H2.4(d) provides, in particular, that a grabrail or handrail must be provided at fixed locations where passengers are required to pay fares.

H2.5 Doorways and doors

Doorways and doors must comply with clause 11 (except clause 11.5.2) of AS 1428.2.

Intent

To specify requirements for doorways and doors in buildings covered by Part H2.

The requirements for doorways and doors in H2.5 were previously located in the Transport Standards.

H2.5 provides that doorways and doors must comply with clause 11 (except clause 11.5.2) of AS 1428.2. The BCA allows for doors that are automatic, power assisted or manual.

H2.6 Lifts

Lift facilities must comply with AS 1735.12.

Intent

To specify requirements for lifts in buildings covered by Part H2.

The requirements for lifts in H2.6 were previously located in the Transport Standards.

H2.6 provides that lift facilities must comply with AS 1735.12.

H2.7 Stairways

Stairs must comply with—

(a)

clause 9.1 of AS 1428.1, including the notes; and

(b)

clause 9.2 of AS 1428.1; and

(c)

clause 13.2, 13.3 and Figures 8 and 9 of AS 1428.2.

Intent

To specify requirements for stairways in buildings covered by Part H2.

The requirements for stairways in H2.7 were previously located in the Transport Standards.

H2.7 provides specifications for accessible stairways in public transport buildings.

The requirement for an accessway under the BCA means that stairways cannot be the sole means of access. However, stairways are acceptable as an optional route on an accessway.

H2.8 Unisex accessible toilet

If toilets are provided, there must be at least one unisex accessible toilet without an airlock that complies with AS 1428.1 clause 10, sanitary facilities.

Intent

To specify requirements for unisex accessible toilets in buildings covered by Part H2.

The requirements for unisex accessible toilets in H2.8 were previously located in the Transport Standards.

H2.8 provides that if toilets are provided, at least one unisex accessible toilet must be provided in accordance with AS 1428.1 (2001) clause 10, sanitary facilities.

H2.9 Location of accessible toilets

Accessible toilets must be in the same location as other toilets.

Intent

To specify requirements for the location of accessible toilets in buildings covered by Part H2.

The requirements for the location of accessible toilets in H2.9 were previously located in the Transport Standards.

H2.9 provides that accessible toilets must be provided in the same location as other toilets.

H2.10 Symbols and signs

(a)

The international symbols for accessibility and deafness in accordance with clauses 14.2 and 14.3 of AS 1428.1 must be used to identify an accessway and which facilities and boarding points are accessible.

(b)

Signs must be placed in accordance with clause 17.4 of AS 1428.2.

(c)

The size of accessibility symbols must comply with Table 1 of AS 1428.2.

(d)

The symbol for accessibility must incorporate directional arrows and words or, if possible, pictograms, to show passengers the way to accessible facilities such as toilets.

(e)

Signs must comply with clause 17.1 and Figure 30 of AS 1428.2.

(f)

If a sign incorporates raised lettering or symbols, they must be at least 0.8 mm above the surface of the sign.

(g)

If an operator or provider supplements a notice with braille characters, they must be placed to the left of the raised characters.

Intent

To specify requirements for symbols and signs in buildings covered by Part H2.

The requirements for symbols and signs in H2.10 were previously located in the Transport Standards.

H2.10 provides requirements for symbols and signs, including where signs should be provided, and the specifications that the signs must comply with.

H2.11 Tactile ground surface indicators

Tactile ground surface indicators must be installed in accordance with AS 1428.4 on an accessway and must indicate changes of direction in accordance with clause 18.1 of AS 1428.2.

Intent

To specify requirements for tactile ground surface indicators (TGSIs) in buildings covered by Part H2.

The requirements for TGSIs in H2.11 were previously located in the Transport Standards.

H2.11 provides that TGSIs must be installed to define key areas on an accessway for people with vision impairment. TGSIs must comply with AS 1428.4 and must indicate changes in direction in accordance with clause 18.1 of AS 1428.2.

H2.12 Lighting

Any lighting provided must comply with minimum levels of maintenance illumination for various situations shown in the notes to clause 19.1 of AS 1428.2.

Intent

To specify requirements for lighting in buildings covered by Part H2.

The requirements for lighting in H2.12 were previously located in the Transport Standards.

H2.12 provides that any lighting provided must comply with the minimum levels of maintenance illumination specified in the notes to clause 19.1 of AS 1428.2.

H2.13 Hearing augmentation

If a public address system is installed, it must comply with clause 21.1 of AS 1428.2.

Intent

To specify requirements for hearing augmentation in buildings covered by Part H2.

The requirements for hearing augmentation in H2.13 were previously located in the Transport Standards.

H2.13 provides that if a public address system is installed, it must comply with clause 21.1 of AS 1428.2.

H2.14 Emergency warning systems

(a)

If an emergency warning system is installed, it must comply with clause 18.2.1, 18.2.2 and 18.2.3 of AS 1428.2.

(b)

In the event of an emergency, provision must be made for people with vision impairment to locate the exit path.

Intent

To specify requirements for emergency warning systems in buildings covered by Part H2.

The requirements for emergency warning systems in H2.14 were previously located in the Transport Standards.

H2.14 provides specifications for emergency warning systems. H2.14(b) provides that, in the event of an emergency, provision must be made for people with vision impairment to locate the exit path.

H2.15 Controls

Controls must comply with clause 11 of AS 1428.1.

Intent

To specify requirements for controls in buildings covered by Part H2.

The requirements for controls in H2.15 were previously located in the Transport Standards.

H2.15 provides that controls must comply with clause 11 of AS 1428.1 which covers door handles and hardware, switches and general purpose outlets (power points) and water taps.