NCC 2019 Volume One Amendment 1
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c
Section G Ancillary provisions

Section G Ancillary provisions

Part G1 Minor structures and components

Delete GP1.2(a) and insert Vic GP1.2(a) as follows:

Performance Requirements

Vic GP1.2 Swimming pool access and water recirculation systems

(a)

A barrier must be provided to a swimming pool and must—

(i)

be continuous for the full extent of the hazard; and

(ii)

be of a strength and rigidity to withstand the foreseeable impact of people; and

(iii)

restrict the access of young children to the pool and the immediate pool surrounds; and

(iv)

have any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.

Application:

Application:

Vic GP1.2(a) only applies to a swimming pool with a depth of water more than 300 mm associated with—

  1. a Class 2 or 3 building or Class 4 part of a building; or
  2. a children’s service.
Delete G1.1(a) and Insert Vic G1.1(a) as follows:

Deemed-to-Satisfy Provisions

Vic G1.1 Swimming pools

(a)

A swimming pool associated with a children’s service, with a depth of water more than 300 mm, must have fencing or other barriers in accordance with AS 1926.1 and AS 1926.2.