NCC 2019 Volume Two Amendment 1
Search the National Construction Code editions
New South Wales variations
This Appendix contains variations for application in New South Wales as follows:
Substitute the definition of appropriate authority as follows:
Substitute the definition of designated bushfire prone area as follows:
Insert definition of Planning for Bush Fire Protection as follows:
Insert definition for spa pool as follows:
Insert in Table 1 of Schedule 4 the following:
No. | Date | Title | Volume Two |
---|---|---|---|
AS 1603 Part 3 | 2018 | Automatic fire detection and alarm systems — Heat alarms See Note 1(b) |
NSW 1.1.4 |
AS 1603 Part 3 | 1996 | Automatic fire detection and alarm systems — Heat alarms See Note 1(a) |
NSW 1.1.4 |
NSW Legislation | 1979 | Environmental Planning and Assessment Act | 3.10.5.0, NSW P2.6.1, NSW Part 3.12.1 |
NSW Legislation | 2000 | Environmental Planning and Assessment Regulation | NSW Schedule 3 |
NSW Legislation | 1992 | Swimming Pools Act | P2.7.1, 3.10.1.0, NSW Schedule 3 |
NSW Legislation | 2018 | Swimming Pools Regulation | P2.7.1, 3.10.1.0 |
Notes associated with NSW Table 1 :
For AS 1603.3:
The 1996 edition has been retained for a transitional period ending on 30 April 2022.
Heat alarms complying with the 2018 edition of AS 1603.3 must be of class type A1 or A2.