NCC 2019 Volume Two Amendment 1
Search the National Construction Code editions
Part 3.8.3 Facilities
Appropriate Performance Requirements
Where an alternative arrangement for facilities is proposed as a Performance Solution to that described in Part 3.8.3, that proposal must comply with—
Compliance with this acceptable construction practice satisfies Performance Requirement P2.4.3 for facilities.
Additional requirements relating to facilities for people with a disability in Class 1b and Class 10a buildings are contained in Volume One of the BCA. These requirements are based on the Disability (Access to Premises – Buildings) Standards (Premises Standards) which are available from the Australian Government Attorney-General's Department website at www.ag.gov.au.
A Class 1 building must be provided with—
a kitchen sink and facilities for the preparation and cooking of food; and
a bath or shower; and
clothes washing facilities, comprising at least one washtub and space in the same room for a washing machine; and
a closet pan; and
a washbasin.
If any of the facilities in (a) are detached from the main building, they must be set aside for the exclusive use of the occupants of the building.
The door to a fully enclosed sanitary compartment must—
open outwards; or
slide; or
be readily removable from the outside of the compartment,
unless there is a clear space of at least 1.2 m, measured in accordance with Figure 3.8.3.3, between the closet pan within the sanitary compartment and the doorway.
3.8.3.3 requires means of removing an unconscious occupant from a fully enclosed sanitary compartment. If the enclosure has gaps that are large enough to allow access for a person into the sanitary compartment, the compartment is not considered enclosed for the purpose of this clause.
Part 3.8.3.4 is added as follows in Tasmania.
Installation of closet fixtures
NCC Volume Three contains a number of plumbing and drainage provisions which are relevant to facilities. These include, but may not be limited to, the following: |
|
Access for maintenance of plumbing and drainage |
Parts B1, B2, B3, C1 and C2 |
Heated water temperature control for facilities used for personal hygiene |
Part B2 |
Installation of plumbing and drainage systems |
Parts C1 and C2 |