Part 3.2.1 Application
Compliance with the acceptable construction practice contained in Parts 3.2.2 to 3.2.5 satisfies Performance Requirements P2.1.1 and P2.2.3 for footings and slabs, provided—
the footing is on a Class A, S, M, M-D, H or H-D site (classified in accordance with AS 2870) with a uniform bearing capacity; and
the slab is not more than 30 m long; and
slabs containing permanent joints (e.g. construction joints) are not used; and
the structure supported by the footing does not contain—
more than two trafficable floors; or
a wall height exceeding 8 m, excluding any gable; and
the footing does not support more than one concrete slab; and
the building does not include wing walls or masonry arches not detailed for movement in
accordance with Cement Concrete and Aggregates Australia TN 61; and
single leaf earth or stone masonry walls do not exceed 3 m in height; and
the site is considered to be normal as defined in Part 3.1.1; and
the site is not located in an alpine area.